Electrical Calc Elite
NEC Code Calculator
| Revenue % | |||||
|---|---|---|---|---|---|
| One-time purchase | 116 | $5.49 – $8.40 | 24.8% | +18.0% | |
| One-time purchase | 115 | $4.69 – $7.90 | 24.8% | +18.0% |
Description
Electrical Calc Elite™ is the electrician's code calculator that follows the NEC® edition your inspector enforces. Size wire, check voltage drop, fill conduit and size motor circuits — offline, in seconds. Answers that come from a code table print which one. One purchase, no subscription.
Ten editions of the National Electrical Code® are built in — NEC® 2026*, 2023, 2020, 2017, 2014, 2011, 2008, 2005, 2002 and 1999 — and every table, correction factor and code reference follows the one you select.
BUILT FOR
Electricians, contractors, estimators, engineers, maintenance techs, inspectors, apprentices studying for the exam, and homeowners checking their work.
WIRE SIZE AND AMPACITY
Required wire size in AWG or kcmil from amps: copper or aluminum, single-phase or three-phase, 60/75/90°C insulation, at 100% or 125%
Ampacity in raceway or free air, from the NEC® ampacity tables (310.16 and 310.17, or the earlier equivalents)
Ambient temperature correction above or below 30°C, in °C or °F
Adjustment for more than three current-carrying conductors in a raceway
Parallel and derated conductor sizing
Circular mils and kcmil for any wire size
VOLTAGE DROP
Volts and percent dropped from one-way length, amps, phase and wire size, with Chapter 9 Table 8 resistance corrected to 60, 75 or 90°C
Wire size for a long run, flagged VD WIRE SIZE when the drop, not the ampacity table, set it
Longest one-way run a wire size will carry inside your limit: 3% by default, or any limit you set
1- or 3-phase, copper or aluminum, feet or meters; wire resistance per 1000 ft on its own key
CONDUIT SIZING AND FILL
12 conduit types: EMT, ENT, FMC, IMC, LFNA, LFNB, LFMC, RMC, PVC schedule 40 and 80, Type A and Type EB
Trade size for a mix of THW/THHW, XHH/XHHW or THHN/THWN conductors
Fill percentage, cross-sectional area and area remaining, from the Chapter 9 tables, with the correct 1-, 2- and over-2-wire fill limits
Maximum conductors of a given size a conduit will take
MOTORS
Full-load current for 1-phase, 3-phase, synchronous and DC motors, from NEC® Tables 430.247, 430.248 and 430.250
Horsepower from amps, and full-load amps from horsepower
Maximum fuse and breaker size from Table 430.52 (430.52(C)(1) in 2023 and 2026) — single-element or dual-element fuse, inverse-time or instantaneous-trip breaker, across seven motor types
Motor overload protection per 430.32(A)(1)
NEMA starter size, per NEMA ICS 2
GROUNDING
Equipment grounding conductor size, per 250.122
Grounding electrode conductor size, per 250.66
POWER, MATH AND CONVERSIONS
Convert between amps, watts, volts, VA, kVA, kW, power factor %, efficiency % and DC resistance
Ohm's Law: enter any two of ohms, volts or amps to get the third
Kirchhoff's Law
Parallel resistance
BTU ↔ kilowatt-hours
Doubles as a standard calculator, with Store and Recall memory keys
CODE REFERENCES YOU CAN CHECK
Wire size, fuse, breaker, overload and grounding answers print the table or section they came from, numbered as your selected edition numbers it. Fuse and breaker cards show the percentage of full-load current used and the current it was applied to.
HELP BUILT IN
Hold any function key to open the manual at that key's own section. A Help key opens it from the front, with worked keystroke examples. A Getting Started guide and the full manual are included.
WORKS OFFLINE
Every calculation runs on the device. No account, no sign-in, no ads, and no waiting on a signal in a basement or a mechanical room.
SUPPORT
Free technical support
[email protected] — https://www.cyberprodigy.com/contact.html
Manual: https://www.cyberprodigy.com/electricalcalcelite/
*NEC® 2026 code data is a one-time in-app purchase. The other nine editions are included.
Electrical Calc Elite™ is not associated with ElectriCalc® Pro and Cyberprodigy LLC is not affiliated with Calculated Industries, Inc.
Last collected from the App Store on